E43-070 · Tolerance Callout & Grade Errors · Hydraulic Cylinder Piston Rod · ★★
The tolerance zone direction was reversed so the rod became tapered the wrong way; the guide bushing scored it and it leaked
[Reversed Direction] A one-way negative deviation should have been specified but the positive direction was used by mistake, making the rod reverse-tapered.
[Scoring] The reverse taper tightened the clearance at the guide bushing, scoring the rod surface and causing leakage.
[Design Omission] The tolerance zone direction should have been made explicit and called out, and no assembly direction check was done.
1) Correct the tolerance zone direction so the fit is right;
2) Make the rod forward-tapered to ease entry;
3) Keep guide bushing clearance at 0.05 to prevent binding;
4) Call out the tolerances according to the assembly direction;
5) Hard-chrome the surface for wear resistance;
6) Inspect the taper on the first piece to verify;
7) Verify free movement with an assembly trial;
8) Re-turn out-of-specification parts.
GB/T 1800.2-2009 Tolerance Zones