Wrong Basis of Tolerances Forces the Shaft to Be Lapped to Match

E43-071 · Tolerance Callout & Grade Errors · Standard Component Shafting · ★★

Problem Symptom

Hole-basis was required but shaft-basis was used, so 45 shafts had to be lapped to match the bores

Root Cause

[Wrong Basis] Hole-basis was required, but shaft-basis was used, so the shafts had to be lapped to match the bores.
[Quantification] Under shaft-basis the shaft tolerance zone is fixed, so each shaft had to be lapped — 45 parts, with labour per part up about 30%.
[Design Omission] The basis of tolerances was never chosen and hole-basis was not specified, a design flaw that forced lapping of the shafts.

Correct Solution

1) Change to hole-basis to ease manufacture;
2) Specify IT7 for the hole and IT6 for the shaft to guarantee the fit;
3) Select standard parts directly to avoid custom design;
4) Lower the lapping grade to save labour;
5) Select per GB/T 1801;
6) Compare process alternatives;
7) Optimise the process to improve efficiency;
8) Assess and dispose of out-of-specification parts.

Checklist

References

GB/T 1801-2009 Limits and Fits