E43-554 · Wrong Tolerance Callout and Grade · Welded frame 2000 long wrongly called to GB/T 1804-f (±0.5) when GB/T 19804-B should apply · ★★
The weldment was held to machined-part grade-f general limits; post-weld shrinkage made the length go out of tolerance, causing batch rework.
[Mechanism] Weldments deform thermally, yet were held to the fine machined-part grade-f general tolerance; process capability could not meet it, so overshoot was widespread.
[Calculation] GB/T 1804-f on 2000mm is ±0.5, while actual welding capability is about ±2 (GB/T 19804 grade B) — a 4× overshoot.
[Design Omission] Machined-part general limits were wrongly applied to a weldment; this design flaw leads to widespread overshoot and rework.
1) Switch the weldment to GB/T 19804 grade-B welding general limits (±2);
2) Machine key mating surfaces after welding, then call out the fine grade on them;
3) Distinguish welding and machining tolerance systems on the drawing;
4) Use an anti-distortion fixture to control shrinkage;
5) Measure the length to grade B on the first article;
6) Use a steel tape / laser distance meter;
7) Stress-relieve after welding, then measure;
8) Sample-inspect the length distribution in production.
GB/T 19804-2005 Welding structure — General dimensional and geometrical tolerances