E43-555 · Wrong Tolerance Callout and Grade · Flange with 4×∅12 holes drawn at position ∅0.2 without datums A|B|C so no gauge could be built · ★★
The position feature-control frame for the hole group omitted the datum; inspection had no datum reference and the assembled holes were offset 0.3, causing mis-drilled holes.
[Mechanism] Position tolerance must be measured against a datum reference frame; omitting the datum leaves the measurement reference undefined, so readings shift with the datum and are distorted.
[Calculation] Without the datum, the ∅0.2 position has no reference; the measured hole-position error reaches 0.3 (relative to the mating part), exceeding the allowance.
[Design Omission] The position frame omitted the 2nd/3rd datum compartments; this design flaw leaves inspection without a reference and causes mis-drilled holes.
1) Add datums A|B|C to the position frame to define the datum reference frame;
2) Set datum A as the mounting face, B as the locating hole, and C as the anti-rotation;
3) Build a three-datum gauge per GB/T 1182;
4) Keep the datum order consistent with assembly locating;
5) Measure position with the gauge on the first article;
6) Re-measure on a CMM with the datum frame established;
7) Check that every geometrical tolerance on the drawing carries its datums;
8) Fit check-pins during assembly to verify hole positions.
GB/T 1182-2018 Geometrical tolerancing—Form, orientation, location and run-out