E43-559 · Wrong Tolerance Callout and Grade · Housing using face A as datum while face A's own flatness was left untoleranced, causing datum drift · ★★
The datum-A face itself was out of flatness control, so hole-position measurements taken against it drifted out of tolerance.
[Mechanism] A datum feature must have its own form controlled before it can serve as a datum; omitting flatness on face A left the datum face itself bent, so derived measurements were distorted.
[Calculation] Face A measured 0.08 flatness; used as a datum, its tilt introduces about 0.08 of hole-position measurement error, exceeding the hole-position allowance of 0.05.
[Design Omission] The datum feature was left without its own form tolerance; this design flaw makes the datum unreliable.
1) Call flatness 0.02 on datum face A to control it first;
2) The datum feature's form tolerance should be tighter than the toleranced feature's;
3) Per GB/T 1182, control datum form first;
4) In inspection, verify the datum face flatness first, then measure the holes;
5) Measure face-A flatness on the first article;
6) Fit the datum plane on a CMM;
7) Give every datum on the drawing a form tolerance;
8) Scrape/lap the assembly datum face for a good fit.
GB/T 1182-2018 Geometrical tolerancing—Form, orientation, location and run-out