Knowledge Base › Tolerance and Fit Error Case › Decimal Places Mismatch Tolerance, Machining Misjudgment

Decimal Places Mismatch Tolerance, Machining Misjudgment

E43-560 · Wrong Tolerance Callout and Grade · Shaft ∅25.0 with tolerance ±0.005 but the basic dimension written to only one decimal place, causing read-out misjudgment · ★

Problem Description

The basic dimension's decimal places did not match the tolerance precision; operators read to 0.1, and overshoots occurred frequently.

Root Cause

[Mechanism] The basic dimension's significant decimals should match the tolerance precision; writing 25.0 against ±0.005 drops the last-place precision information and leads to operator misjudgment.
[Calculation] Tolerance ±0.005 needs 3 decimals, yet 25.0 was drawn with only 1; the reading resolution mismatches 0.005, introducing a 0.01 misread.
[Design Omission] The decimal places did not match the tolerance precision; this design flaw leads to read-out misjudgment and overshoot.

Corrective Solution

1) Write the basic dimension ∅25.000, aligned to the tolerance's 3 decimals;
2) Unify decimal places per GB/T 1800;
3) Match the drawing's dimension precision to the tolerance;
4) Select a 0.001 instrument to match the read-out;
5) Recheck reading consistency on the first article;
6) Sync the decimal places on the process sheet;
7) Review checks the dimension-place convention;
8) Batch-verify there is no misread.

Checklist

Reference

GB/T 1800.1-2020 Limits and fits — Basis of tolerances

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »