E43-561 · Wrong Tolerance Callout and Grade · Taper-pin hole with 1:50 taper left without an angular tolerance and run to general ±30′, causing low taper contact · ★★
The taper angle was left untoleranced and run to a general angular limit of ±30′; the tapered contact was only 50%, causing looseness.
[Mechanism] Tapered-fit angular precision directly determines the contact rate; omitting the tolerance ran it to a coarse general angular limit, and the taper-angle error shifted the contact band.
[Calculation] A general angle of ±30′ gives a generatrix deviation δ = L·tan(30′) ≈ 100×0.0087 = 0.87mm on the taper, dropping contact to 50%.
[Design Omission] The taper angle lacked a dedicated angular tolerance; this design flaw leads to low contact and looseness.
1) Call an angular tolerance of ±2′ on the taper to secure contact rate;
2) Grade the taper tolerance AT4 per GB/T 11334;
3) Check contact ≥80% with a taper gauge and bluing;
4) Measure the taper angle and contact rate on the first article;
5) Mark the taper tolerance symbol on the drawing;
6) Measure the angle with a sine bar + gauge blocks;
7) Lap the taper pin for full contact;
8) Measure axial location during assembly.
GB/T 11334-2005 GPS — Taper tolerance