Radius and Diameter Tolerance Mixed Callout, Turning Overshoot

E43-562 · Wrong Tolerance Callout and Grade · Turned groove drawn R25±0.05 when the actual requirement was diameter ∅50, causing radius-based turning error · ★

Problem Description

Radius and diameter callouts were confused; operators controlled to R25 on one side, and the measured diameter ∅50.1 went out of tolerance.

Root Cause

[Mechanism] A rotational body should be dimensioned as a diameter; marking it as a radius led to one-sided measurement, so the diameter error, twice the radius error, went unnoticed.
[Calculation] R25±0.05 converts to diameter ∅50±0.1, double the design diameter allowance of ∅50±0.05.
[Design Omission] A rotational dimension was wrongly called out as a radius; this design flaw leads to diameter overshoot.

Corrective Solution

1) Always dimension rotational bodies as diameter ∅50±0.05;
2) Use R only for non-rotational arcs;
3) Follow the dimensioning rules of GB/T 4458.4;
4) Measure diameter, not radius, on the first article;
5) Use an outside micrometer to measure ∅;
6) Distinguish where R vs. ∅ applies on the drawing;
7) Make diameter control explicit on the process sheet;
8) Sample-inspect diameter in production.

Checklist

Reference

GB/T 4458.4-2003 Mechanical documentation — Dimensioning