E43-601 · Tolerance Annotation and Grade Error · A support bracket where the design omitted flatness and followed GB/T 1184 grade K, leaving the mounting face wavy with low contact ratio · ★★
Flatness was omitted on the mounting face, so it was made to the unsigned-geometric K grade (0.1); contact ratio was low, and vibration caused loosening.
[Mechanism] Critical mounting faces must have flatness individually annotated; when omitted, they are made to a low unsigned-geometric grade, and face waviness makes the contact ratio insufficient.
[Calculation] Unsigned K-grade flatness is 0.1 over 300 mm, while function requires 0.03; waviness drops the contact ratio to 40%, and bolts loosen.
[Design Omission] Flatness was omitted on the mounting face; this design defect leads to low contact ratio and loosening.
1) Specify flatness 0.03 on the mounting face to ensure contact;
2) Set the grade by function per GB/T 1184;
3) Check contact ratio with blued layout fluid at ≥70%;
4) On the first article, measure flatness and contact ratio;
5) Individually annotate geometric tolerances on critical faces on the drawing;
6) Finish-grind / scrape to keep flat;
7) Tighten bolts symmetrically;
8) Verify with a vibration test.
GB/T 1184-1996 Geometrical tolerancing—Unsigned tolerances for linear and angular dimensions