E43-602 · Tolerance Annotation and Grade Error · A housing hole group where the design datum order A|B|C was reversed to C|B|A, causing the wrong primary locating face and hole-position shift · ★★
The datum order was reversed: the primary datum was chosen as a small face, the main assembly locating face was not constrained first, and hole positions shifted by 0.2.
[Mechanism] The datum order expresses locating priority; the first datum should be the largest main locating face. Reversing it locates a secondary face first, and over-locating shifts hole positions.
[Calculation] After reversal, the small end face became the first datum; residual tilt of 0.1 on the main face was lever-magnified, shifting far-end holes by 0.2, exceeding the allowable 0.1.
[Design Omission] The datum order was reversed; this design defect leads to wrong locating relationships and hole-position shift.
1) Change the datum order to A (large mounting face) | B (locating hole) | C (anti-rotation);
2) Set the datum order per the assembly locating sequence;
3) Follow the datum-system rules in GB/T 17851;
4) Locate the inspection fixture in the correct order;
5) On the first article, measure hole positions per A|B|C;
6) Check the datum order on the drawing;
7) Clamp the main face first in the fixture;
8) Verify locating after assembly.
GB/T 17851-2010 Geometrical tolerancing—Datum and datum systems