E43-646 · Surface Roughness Mismatch with Fit · A mating shaft where the drawing omitted the Ra symbol so the part was machined to unspecified roughness and the fit surface failed from being too rough · ★★
The roughness symbol was omitted on the mating surfaces, which were then rough-machined to the shop default, leaving the fit surfaces too rough to meet performance.
[Mechanism] Mating surfaces must carry a roughness symbol; when it is omitted, the surface is machined to the unspecified or default roughness, which loses roughness control and impairs the fit function.
[Calculation] The omitted default Ra3.2 is four times rougher than the Ra0.8 the fit requires, causing fit failure (looseness, leak, wear).
[Design Omission] The roughness symbol was omitted on the mating surface; design defect → failure from excessive roughness.
1) Add the Ra symbol on mating surfaces to state the requirement explicitly;
2) State the unspecified roughness value in the upper-right corner of the drawing;
3) Specify Ra surface by surface according to function;
4) Measure Ra of each surface on the first article;
5) Review the drawing to confirm no omitted symbols;
6) Sync the Ra values onto the process sheet;
7) Measure Ra with proper instruments;
8) Verify the fit function.
GB/T 131-2006 Geometrical product specifications — Surface texture designation