E43-648 · Surface Roughness Mismatch with Fit · A long-period texture surface marked Ra0.8 without a sampling length, so waviness was included in the evaluation and the reading was distorted into a false out-of-tolerance · ★
The sampling length was not specified on the roughness callout, so the evaluation included long-wave waviness and the Ra reading was falsely high, causing parts to be misjudged as out of tolerance.
[Mechanism] Roughness must be filtered with a proper cutoff length λc; when it is not specified, long-wave waviness is included in the evaluation and the Ra reading is falsely high and misjudged.
[Calculation] With λc=0.8 including waviness, the Ra reading rose from 0.8 to a false 1.5; judged against 0.8 it was out of tolerance, but the cause was waviness, not roughness.
[Design Omission] The sampling length was not specified; design defect → distorted evaluation.
1) Select and mark λc per GB/T 1031;
2) Separate waviness from roughness in the evaluation;
3) Set the instrument to match λc;
4) Re-measure the first article at the chosen λc;
5) Mark the sampling length on the drawing;
6) Evaluate waviness separately when needed;
7) Agree between supplier and purchaser on the filter;
8) Re-measure to verify.
GB/T 1031-2009 Surface roughness — Parameters and their values