E43-692 · Taper and Angle Fit Error · Working taper plug gauge (go/no-go ends) for a taper bore where a worn gauge reference face caused a false accept, leading to insufficient taper contact after assembly and return · ★★★
A taper bore was checked with a worn plug gauge; wear on the gauge reference face shifted the axial-position reading and the bore was wrongly accepted, but in assembly the taper contact rate proved insufficient and the part was returned.
[Mechanism] A taper plug gauge judges taper bore diameter from the distance between its end face and the bore mouth; wear on the gauge shifts the datum, distorts the reading, and lets out-of-tolerance bores escape detection.
[Calculation] 0.1mm of wear on the gauge face biases the taper-diameter reading, so an out-of-tolerance taper angle is wrongly accepted and the contact rate is insufficient.
[Design Omission] A worn gauge was still used without recalibration; the design defect leads to misjudgment and missed rejection.
1) Periodically verify and calibrate the taper plug gauge;
2) Scrap and replace worn gauges;
3) During inspection, read that the axial position lies within the graduation marks;
4) On the first article, recheck the taper angle on a CMM;
5) Check the contact rate by bluing;
6) Store gauges in a dedicated cabinet to prevent knocks;
7) Maintain a gauge log;
8) Verify contact during assembly.
GB/T 11852-2003 Tolerances and specifications for cone gauges