E43-691 · Taper and Angle Fit Error · Tool-microscope dovetail slide designed 60°±1′ but measured 60°8′, giving a 0.03mm dovetail clearance and fine-motion positioning drift · ★★★
The dovetail slide angle was off by +7′ from 60°, mismatching the ways’ dovetail; the fit clearance was 0.03mm, causing 0.01mm of positioning drift during fine inching.
[Mechanism] Precision dovetails rely on a precise 60° angular fit; an angle error increases clearance, makes the slide drift sideways during inching, and destabilizes positioning.
[Calculation] A 7′ angle error produces a 0.04mm clearance over a 20mm dovetail height and 0.01mm of inching drift, exceeding the 0.002mm precision requirement.
[Design Omission] The dovetail angle was match-ground out of tolerance; the design defect leads to clearance and drift.
1) Match-grind both dovetail angles to 60°±1′, matching each other;
2) Inspect with an angle gauge;
3) Lap the gib to full contact;
4) Adjust the clearance to 0.002–0.005mm;
5) Measure the inching drift on the first article;
6) Keep the way surface Ra≤0.2;
7) Specify the dovetail angle on the drawing;
8) Verify positioning accuracy.
GB/T 1804-2000 General tolerances — tolerances for unlisted angles