E43-702 · Taper and Angle Fit Error · Spindle taper bore with residual swarf where chips lifted the taper on toolholder installation, locally breaking contact, dropping the contact rate, and giving 0.025mm toolholder runout · ★★★
Fine swarf remained in the spindle taper bore; when the toolholder was installed, the chips lifted one side of the taper, locally breaking contact, dropping the contact rate, and giving 0.025mm of toolholder radial runout with chatter marks.
[Mechanism] Taper locating requires a clean, fully contacting surface; residual chips lift the taper locally, reduce the contact area, and tilt the locator, causing runout.
[Calculation] A 0.05mm chip lifts the taper on one side, drops the contact rate by 30%, and gives 0.025mm of toolholder wobble, which exceeds the limit.
[Design Omission] The taper bore had no chip-blowing/cleaning provision; the design defect lets residual swarf affect contact.
1) Blow swarf out of the taper bore every time a tool is installed;
2) Add automatic compressed-air chip blowing to the taper bore;
3) Wipe the toolholder taper clean;
4) Measure toolholder runout on the first article;
5) Check the contact rate by bluing;
6) Keep the taper bore free of nicks and burrs;
7) Follow cleaning work instructions;
8) Verify chatter marks by cutting.
GB/T 3837-2001 7:24 tapers for hand and machine use