E43-739 · Thread Tolerance and Fit Error · A flange bolt's loose thread fit left poor flank contact after tightening, and running vibration relaxed the preload and leaked at the flange · ★★★
A flange bolt threaded with a loose fit (6H/8g) had insufficient flank contact after tightening; under running vibration the flank micro-motion relaxed the preload, and the flange face lost pressure and leaked.
[Mechanism] Bolt preload is maintained by tight flank contact; a loose fit leaves poor flank contact, vibrational micro-motion relaxes it, and preload is lost and leaks.
[Calculation] The small 8g pitch diameter widens flank clearance and lowers effective contact; under vibration the preload relaxes 20%, the flange contact pressure becomes insufficient, and it leaks.
[Design Omission] The thread fit was too loose - a design defect leading to preload relaxation and leakage.
1) Choose a 6H/6g thread fit to reduce clearance;
2) Inspect with GO/NO-GO gauges;
3) Add anti-loosening measures;
4) Tighten by the turn-of-nut method to guarantee preload;
5) On first articles, measure preload relaxation;
6) Keep the thread form complete;
7) Call out fit class on the drawing;
8) Verify sealing under running.
GB/T 197-2018 General-purpose metric screw threads — Tolerances