E43-745 · Thread Tolerance and Fit Error · An equipment tensioner's left-hand thread was wrongly fitted with a right-hand nut and jammed after two turns, or loosened backward under the running direction · ★★★
A tensioner's left-hand thread was wrongly mated with a right-hand nut; after two turns the thread phases opposed and jammed, impossible to mate. Where similar parts were mixed, a right-hand thread mistaken for left-hand loosened backward under the running direction.
[Mechanism] Left- and right-hand threads oppose in hand and cannot mate; mixing them jams engagement, or leaves the hand opposing the load direction so the joint loosens in service.
[Calculation] Left- and right-hand hands oppose, so after a few turns the flanks push backward and jam; a wrong hand makes the working direction self-loosen.
[Design Omission] Left- and right-hand parts had no clear marking and were easily mixed - a design defect leading to wrong assembly and loosening.
1) Mark left-hand threads per standard (LH) and add a visual mark;
2) Store left- and right-hand parts in separate zones to prevent mixing;
3) Verify hand at assembly;
4) Verify mating on the first article;
5) Match the load direction to the thread hand;
6) Gauge threads by their hand;
7) Call out the hand on the drawing;
8) Verify anti-loosening in running.
GB/T 197-2018 General-purpose metric screw threads — Tolerances