E43-748 · Thread Tolerance and Fit Error · Anaerobic adhesive used on threads fitted too tightly with no film clearance, squeezing out the adhesive and causing lock failure or difficult assembly · ★★★
An anaerobic threadlocker was used on the joint, but the threads were fitted too tightly (near-zero clearance), leaving no room for the adhesive. As the fastener was driven in, the adhesive was squeezed out, the bond film was incomplete, the locking strength was insufficient, and the joint loosened.
[Mechanism] Anaerobic threadlocker must cure as a film within the thread clearance; a fit so tight that no clearance remains squeezes out the adhesive, leaves no effective film, and defeats the lock.
[Calculation] A fit clearance <0.05mm leaves too thin a bond film, cuts locking strength by 50%, and loosens under vibration.
[Design Omission] The bonded thread fit was too tight to hold adhesive — a design defect leading to lock failure.
1) Keep a moderate clearance on bonded threads (6H/6g);
2) Select an anaerobic adhesive of suitable viscosity;
3) Clean and degrease the threads;
4) On first articles, measure the prevailing torque;
5) Apply the correct adhesive amount;
6) Allow adequate cure time;
7) State the threadlocking requirement on the drawing;
8) Verify anti-loosening performance.
GB/T 197-2018 General-purpose metric screw threads — Tolerances