E43-035 · Rolling Bearing Fit Errors · Fan Bearing Housing · ★★★

Problem Symptom

Inner ring on the shaft was H7/h6 and loose; the inner ring crept and wore; life 3000h (should be 20000h)

Root Cause

[Loose Fit] The journal was specified H7/h6, a clearance fit, which is unsuitable for a bearing; the inner ring crept slightly on the shaft.
[Creep Wear] Under alternating load the inner ring slid circumferentially, wearing a 0.05 groove in the mating surface and increasing clearance sharply.
[Design Omission] A rotating inner ring should use H7/k6 or H7/m6 to guarantee slight interference, and the speed and load were not checked when selecting the fit.

Correct Solution

1) Change the journal to H7/k6 or H7/m6 for slight interference to prevent rotation;
2) Select the fit grade to match the speed and load conditions;
3) Control journal roundness to ≤0.004 to preserve the fit;
4) Assemble the bearing heated to avoid damaging the mating surfaces;
5) Confirm on the first piece that the inner ring shows no creep;
6) Monitor temperature and vibration during operation to detect failure;
7) Verify life on the bench at ≥20000h to confirm durability;
8) Bring bearing fit verification into the design review.

Checklist

References

GB/T 307.3-2017 Rolling Bearings — General Technical Rules