Housing Bore Too Tight Causes the Outer Ring to Crack

E43-036 · Rolling Bearing Fit Errors · Gearbox Bearing Bore · ★★★

Problem Symptom

Housing bore H7/p6 was too tight and the outer ring cracked

Root Cause

[Too Tight] The housing bore was specified H7/p6 with 0.04 interference; after assembly the outer ring carried a preload stress σ=0.04×2.1e5/100=84MPa, which added to the working stress beyond the limit.
[Cracking] The thin-walled outer ring subjected to a large interference distorted the rolling element raceway, concentrating contact stress until it cracked.
[Design Omission] A rotating outer ring should use a loose transition fit such as H7/J7 or H7/K7; only a stationary housing bore should take a tighter fit.

Correct Solution

1) Change the housing bore to H7/J7 or H7/K7, a loose transition fit, to ease assembly;
2) Select the fit according to whether the ring rotates or is stationary, to prevent rotation;
3) Control housing bore roundness to ≤0.006 to preserve the fit;
4) Add axial location to the outer ring to prevent migration;
5) Monitor assembly force to guard against excessive interference;
6) Verify on the first piece that there is no cracking risk;
7) Monitor for abnormal noise during operation to detect failure;
8) Bring bearing fit verification into the design review.

Checklist

References

GB/T 307.3-2017 Rolling Bearings — General Technical Rules