E43-082 · Rolling Bearing Fit Errors · Gearbox Bearing Housing · ★★
Outer ring and housing bore were designed H7 but P7 was used, which was too tight and cracked 1 part during assembly
[Fit Too Tight] An H7 clearance was designed, but P7 interference was used by mistake, putting the outer ring under preload.
[Cracking] The excessive interference deformed the outer ring into an ellipse, concentrating the rolling element load and cracking it.
[Design Omission] The outer ring should use a floating H7 fit, and the fit selection was not carried out.
1) Change the outer ring fit to H7;
2) Specify housing bore roughness Ra1.6;
3) Use clearance class C3;
4) Follow GB/T 275;
5) Control the press force;
6) Check the fit on the first piece;
7) Monitor vibration;
8) Re-bore out-of-specification housings.
GB/T 275-2015 Bearing Fits