Wrong Angular Contact Bearing Preload Causes Excessive Temperature Rise

E43-083 · Rolling Bearing Fit Errors · Spindle Angular Contact Bearing · ★★★

Problem Symptom

Preload designed at 120N but actual 300N; the temperature rose 50℃ and the grease failed

Root Cause

[Preload Too High] The design preload was 120N but 300N was applied by mistake, deforming the contact angle.
[Temperature Rise] The high preload increased the friction power Q∝Fp, so the temperature rise ΔT exceeded the limit.
[Design Omission] The preload should be set from the speed and the temperature measured, but no preload calculation was made.

Correct Solution

1) Set the preload to 120N;
2) Determine the preload according to speed;
3) Use spring washers between the bearings;
4) Keep the temperature rise ≤35℃;
5) Select a suitable grease;
6) Check the preload on the first piece;
7) Measure temperature by infrared;
8) Adjust the spacer washers when out of specification.

Checklist

References

GB/T 307.3-2017 Rolling Bearings