Excessive Coaxiality Between the Bearing Bore and End Cap Spigot Causes Binding

E43-262 · Rolling Bearing Fit Errors · Gearbox Input Shaft Bearing Bore ∅90 and End Cap Spigot, coaxiality designed ≤0.02, actual 0.08 · ★★

Problem Symptom

A spigot coaxiality of 0.08mm (allowable 0.02) offset the outer ring by 0.04 and halved the clearance c=0.08, causing binding

Root Cause

[Mechanism] The poor spigot coaxiality made the end cap press off-axis and the outer ring took a side load.
[Calculation] A coaxiality t=0.08 offset the outer ring by 0.04=0.5t, so the residual clearance c'=c-0.04=0.04, and the contact stress p0∝1/√c' rose by √2, causing binding.
[Design Omission] The spigot coaxiality was not controlled; this design flaw caused the binding.

Correct Solution

1) Keep the spigot coaxiality ≤0.02 to prevent off-axis clamping;
2) Bore the bore and spigot in one setup to guarantee concentricity;
3) Match the end cap spigot;
4) Select and match the bearings;
5) Inspect the clearance ≥0.04 after installation;
6) Turn by hand to confirm free movement;
7) Check the temperature rise;
8) Bring the coaxiality onto the drawing.