E43-272 · Rolling Bearing Fit Errors · Excavator Slewing Bearing ∅1000 Mounting Face, perpendicularity designed ≤0.03, actual 0.1 · ★★
A perpendicularity of 0.1mm between the mounting face and the bolt holes (allowable 0.03) offset the tooth flank load by 40%, with a risk of tooth breakage
[Mechanism] The perpendicularity error tilted the gear ring and the meshing became unevenly loaded.
[Calculation] A perpendicularity of 0.1 gave a tooth flank load offset ΔF=40%, and the contact stress p0=1.4p_avg exceeded the fatigue limit and broke the tooth.
[Design Omission] The mounting face perpendicularity was not controlled; this design flaw caused the tooth breakage.
1) Control the mounting face perpendicularity ≤0.03 to prevent uneven loading;
2) Finish mill the seat face to preserve flatness;
3) Tighten the bolts with even torque to prevent loosening;
4) Correct the gear ring tooth alignment;
5) Inspect the mesh contact pattern after installation;
6) Trial run and listen for abnormal noise;
7) Verify even load distribution;
8) Bring perpendicularity into the acceptance criteria.
GB/T 1182-2018 Geometrical Tolerances