Clearance in the Shield Body Bore Lets the TBM Main Bearing Outer Ring Wander and Destroys the Seal

E43-273 · Rolling Bearing Fit Errors · TBM Main Bearing Outer Ring ∅3000, designed K7 interference 0.05, actual clearance 0.3 · ★★

Problem Symptom

A clearance of 0.3mm between the outer ring and the shield body (allowable 0.05) let the outer ring wander 0.3 and crush the seal, leaking grease

Root Cause

[Mechanism] The large clearance let the outer ring wander and the seal lip followed it and failed.
[Calculation] A clearance δ=0.3 gave 0.3 of outer ring wander, 6 times the allowable, and the seal lip tracked unstably and was crushed.
[Design Omission] No interference fit was specified; this design flaw caused the seal failure.

Correct Solution

1) Change the shield body bore to K7 interference 0.02~0.05 to prevent wander;
2) Add circumferential anti-rotation to the outer ring;
3) Use dual seals to prevent seepage;
4) Finish bore the hole to guarantee roundness;
5) Inspect the wander ≤0.05 after installation;
6) Perform a seal pressure test;
7) Monitor the grease pressure;
8) Bring the fit onto the drawing.

Checklist

References

GB/T 288-2011 Rolling Bearings — Self-Aligning Roller Bearings

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL