❌ Error Case Studies

📚 Technical Articles

Unbalanced Rotor Combined with a Loose Fit Causes Centrifuge Vibration

E43-282 · Rolling Bearing Fit Errors · Horizontal Centrifuge Spindle Bearing 6212 ∅60, designed dynamic balance G2.5 with k5 tight fit, actual unbalance 20g·mm with clearance · ★★

Problem Symptom

A spindle unbalance of 20g·mm (allowable 5) combined with the loose fit pushed the vibration above 4.5mm/s, double the limit

Root Cause

[Mechanism] The unbalanced shaft ran out and the loose fit amplified the vibration.
[Calculation] The 20g·mm unbalance raised the vibration v0 above 4.5mm/s, and the loose fit doubled it to 9mm/s, above the allowable.
[Design Omission] No dynamic balancing was done and the fit was loose; this design flaw caused the vibration.

Correct Solution

1) Dynamically balance the spindle to G2.5 to reduce vibration;
2) Change the shaft to a k5 tight fit to prevent loosening;
3) Select P5 grade for higher precision;
4) Hot assemble to prevent damage;
5) Inspect the vibration ≤2.8 after installation;
6) Run a high-speed run-in;
7) Check the temperature rise;
8) Bring balancing into the process specification.

Checklist

References

GB/T 307.3-2017 Rolling Bearings — General Technical Rules

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL