Excessive Axial Clearance in the Agitator Vertical Shaft Bearing Causes Wall Scraping

E43-283 · Rolling Bearing Fit Errors · Reactor Agitator Vertical Shaft Bearing 22218 ∅90, axial limit clearance designed 0.1, actual 0.4 · ★★

Problem Symptom

An axial clearance of 0.4mm (allowable 0.1) let the impeller sink 0.4 and strike the tank wall, scraping and wearing it

Root Cause

[Mechanism] The large axial clearance let the impeller sink and strike the tank wall.
[Calculation] A clearance δ=0.4 sank the impeller by 0.4, and it scraped the wall.
[Design Omission] No axial location was provided; this design flaw caused the wall scraping.

Correct Solution

1) Control the axial location clearance at 0.05~0.1 to prevent sinking;
2) Use a thrust bearing to carry the axial load;
3) Use K7 for the housing bore to prevent loosening;
4) Select 22218 for the load capacity;
5) Inspect the axial position after installation;
6) Check with a trial rotation;
7) Check the temperature rise;
8) Bring the axial location onto the drawing.

Checklist

References

GB/T 288-2011 Rolling Bearings — Self-Aligning Roller Bearings