E43-284 · Rolling Bearing Fit Errors · Bucket Elevator Head Wheel Bearing 6210 Inner Ring ∅50, journal Ra0.8 designed, actual Ra3.2 · ★★
The journal surface at Ra3.2 (should be Ra0.8) raised the fretting wear rate 3 times and the interference was lost after 300 hours
[Mechanism] The high roughness made the contact micro-projections wear and the fit loosened.
[Calculation] Ra3.2 gives a fretting wear rate (3.2/0.8)≈4 times that of Ra0.8 (measured about 3 times), so the interference was lost after 300 hours.
[Design Omission] The surface roughness was not controlled; this design flaw caused the loosening.
1) Grind the journal to Ra0.8 to reduce wear;
2) Select a k6 tight fit;
3) Hot assemble to prevent damage;
4) Harden the surface for wear resistance;
5) Inspect the interference after installation;
6) Run in and listen for abnormal noise;
7) Check the temperature rise;
8) Bring the roughness onto the drawing.
GB/T 275-2015 Rolling Bearings — Fits with Shafts and Housings