Insufficient Traction Machine Bearing Interference Causes Sheave Runout

E43-295 · Rolling Bearing Fit Errors · Elevator Traction Machine Bearing 6314 Inner Ring ∅70, designed k6 interference 0.03, actual 0.002 · ★★

Problem Symptom

An inner ring interference of 0.002 (should be 0.03) let the inner ring slip and the traction sheave ran out 0.2mm, above the limit

Root Cause

[Mechanism] The insufficient interference let the inner ring turn relative to the shaft and the sheave ran out.
[Calculation] The contact pressure p=δE/d=0.002×2.1e5/70=6MPa, but transmitting the torque needs ≥90MPa corresponding to the designed 0.03; the shortfall caused slipping and 0.2 of sheave runout.
[Design Omission] The interference was not controlled; this design flaw caused the sheave runout.

Correct Solution

1) Change the shaft to k6 interference 0.02~0.04 to prevent slipping;
2) Assemble heated to prevent damage;
3) Harden the journal for wear resistance;
4) Select 6314 for the load capacity;
5) Inspect the interference after installation;
6) Inspect the sheave runout ≤0.05;
7) Check the temperature rise;
8) Bring the interference onto the drawing.

Checklist

References

GB/T 275-2015 Rolling Bearings — Fits with Shafts and Housings