E43-803 · Key-and-Spline Fit Error · A minor-diameter-centered spline with wrong bore minor-diameter tolerance band causes either centering interference and difficult assembly, or loose centering and poor concentricity · ★★★
For a minor-diameter-centered spline, the internal spline minor-diameter tolerance band was chosen wrong (H11, too loose): centering clearance is large and concentricity is poor; choosing interference instead makes assembly difficult — the centering fit is improper either way.
[Mechanism] The spline centering-diameter tolerance band determines centering accuracy; a wrong choice gives either loose centering (poor concentricity) or interference (difficult assembly).
[Calculation] Minor-diameter H11 has 0.06mm more clearance than H7, giving 0.06mm concentricity error and rotational wobble.
[Design Omission] The centering-diameter tolerance band is chosen improperly, a design defect leading to poor centering.
1) Choose the centering-diameter tolerance band by accuracy (H7/g6, etc.);
2) Inspect internal/external centering diameters;
3) On the first part, measure concentricity;
4) Hold centering-surface grinding accuracy;
5) Keep moderate tooth-side clearance;
6) Refine centering-surface Ra;
7) Call out centering tolerance band on the drawing;
8) Verify in rotation.
GB/T 1144-2001 Straight-sided splines — Dimensions, tolerances and inspection