Knowledge Base › Tolerance and Fit Error Case › Key Loosens and Walks Out Under Dynamic Load

Key Loosens and Walks Out Under Dynamic Load

E43-804 · Key-and-Spline Fit Error · A flat key on a reciprocating dynamic-load shaft with no axial retention creeps along the keyway under reciprocating impact, gradually walks out of the slot, and loses torque transmission · ★★★

Problem Description

A flat key on a reciprocating dynamic-load shaft has no axial retention (no end stop); under reciprocating impact, the key creeps axially in the keyway, gradually walks out of the slot, and finally loses torque transmission while the hub slips.

Root Cause

[Mechanism] A key under dynamic load must be axially retained against walking; without retention, reciprocating impact makes it creep axially, walk out of the slot, and fail.
[Calculation] Every thousand reciprocating impacts walk the key 0.1mm; cumulative walk-out clears the slot, torque contact is lost, and the joint fails.
[Design Omission] The key has no axial retention, a design defect leading to walk-out failure.

Corrective Solution

1) Add a retaining ring or set screw at the key end for axial retention;
2) Use a key-end countersunk screw when necessary;
3) On the first part, measure axial creep under dynamic load;
4) Match key length to slot;
5) Keep key-side fit moderate;
6) Add a locking feature;
7) Call out axial retention on the drawing;
8) Verify under dynamic load.

Checklist

Reference

GB/T 1096-2003 Type A flat keys