E43-807 · Key-and-Spline Fit Error · Uneven indexing during internal spline shaping causing varying tooth thickness, unequal backlash in mesh with external spline, eccentric-load wear · ★★★
In shaping the internal spline, uneven indexing makes tooth thickness vary from tooth to tooth; backlash per tooth in mesh with the external spline is unequal, load concentrates on the thicker-toothed (smaller-clearance) teeth, and eccentric-load wear results.
[Mechanism] Spline teeth should have uniform thickness for even load sharing; uneven shaping indexing makes tooth thickness and clearance unequal, causing eccentric-load wear.
[Calculation] A 0.03mm tooth-thickness variation creates unequal backlash among teeth; load concentrates on the tightest tooth, raising eccentric-load stress and wear.
[Design Omission] Uneven shaping indexing; design omission leads to uneven tooth thickness and eccentric load.
1) Ensure shaping indexing accuracy for uniform tooth thickness;
2) Inspect with a spline composite gauge;
3) Measure tooth thickness of each tooth on the first article;
4) Check per-tooth contact with bluing;
5) Maintain shaping machine accuracy;
6) Ensure tooth-flank wear resistance;
7) Specify tooth-thickness tolerance on the drawing;
8) Verify under torque transmission.
GB/T 1144-2001 Straight-sided splines — Dimensions, tolerances and inspection