E43-808 · Key-and-Spline Fit Error · h11 mistakenly selected for key width causing wide scatter and uneven loose/tight fit with N9 keyways, some too loose and some too tight · ★★★
The flat key width was mistakenly assigned the h11 tolerance band (wide scatter); key width within the same batch scatters by 0.09mm, the fit with N9 keyways ranges from loose to tight, some pairs rattle with play, and others are too tight to assemble.
[Mechanism] The key-width tolerance band should follow the standard (h8/h9); mistakenly choosing h11 widens the scatter and makes the fit with the keyway inconsistent.
[Calculation] The 0.09mm h11 key-width scatter spans the fit from interference to clearance; some pairs rattle and others are hard to assemble.
[Design Omission] Improper key-width tolerance band selection; design omission leads to inconsistent fit.
1) Apply the standard h8/h9 tolerance band to key width;
2) Inspect key width with a snap gauge;
3) Check fit tightness on the first article;
4) Match the keyway to the fit;
5) Select keys per GB/T 1096;
6) Check key-side contact;
7) Specify key-width tolerance on the drawing;
8) Verify after assembly.
GB/T 1096-2003 Type A flat keys