E43-892 · Seal and Clearance Fit Error · A pump-flange rubber flat gasket designed thickness 3±0.2 measured 2.5 (beyond lower deviation), so compression cannot fill the gap, flange flatness error is uncompensated, and water seeps · ★★
A rubber flat gasket on a centrifugal pump inlet/outlet flange measured 2.5 thick, below the designed 3±0.2 lower limit; after compression it cannot fill the 0.3 flange-face flatness error, leaving local non-contact and water seepage.
[Mechanism] A non-metallic flat gasket fills flange-face flatness errors by compressing its own thickness and creates sealing contact pressure; with insufficient thickness the gap-filling and compression reserve are inadequate.
[Calculation] Fillable flatness ≈ compression = thickness × compression ratio; thickness 2.5 × 30% = 0.75, which is > the 0.3 flatness, but the lower deviation leaves insufficient contact pressure and local areas not fully compressed.
[Design Omission] Incoming gasket thickness was taken at the lower deviation without inspection, and flange-face flatness was not controlled — a design defect leading to poor gap filling and local leakage.
1) Hold gasket thickness at 3±0.2 per GB/T 9126, and check the lower limit with calipers on first articles;
2) Hold flange-face flatness ≤0.2 to reduce the gap-filling requirement;
3) Size fill amount = thickness × compression ratio, quantitatively;
4) Set bolt torque from the gasket factor, holding compression 20%~40%;
5) Inspect incoming gasket Shore hardness to ensure contact pressure;
6) On first articles, run a 0.6MPa hydrostatic test with no seepage, to verify;
7) Call out gasket thickness tolerance and flange flatness on the drawing;
8) If thickness is insufficient, replace with a conforming gasket.
GB/T 9126-2008 Non-metallic flat gaskets for pipe flanges — Dimensions