High-Temperature Shafting Clearance Closes Up and Seizes

E43-047 · Uncompensated Thermal Distortion · Drying Equipment Sprocket Shaft · ★★★

Problem Symptom

At a working temperature of 180℃ the 0.05 clearance disappeared and the shaft seized; 6 line stops per month

Root Cause

[Thermal Expansion] With steel α=12e-6, a 160℃ rise produced elongation ΔL=αLΔT=12e-6×200×160=0.384mm, which consumed the original 0.05 clearance.
[Seizing] The elongation drove the bearing preload into interference, so the rotational resistance rose sharply and the shaft seized.
[Design Omission] High-temperature shafting should reserve a thermal expansion clearance or use a large-clearance H7/g6 fit, and no thermal distortion calculation was done.

Correct Solution

1) Reserve a thermal expansion clearance of ≥ΔL+0.1 to prevent seizing;
2) Change the fit to H7/g6 with a large clearance to absorb the expansion;
3) Carry out a thermal distortion calculation and compensation to prevent shaft lock-up;
4) Select high-temperature grease for the bearings to prevent failure;
5) Provide a floating end in the axial direction to release the elongation;
6) Run a hot trial on the first piece to verify free movement;
7) Monitor temperature rise to prevent overheating;
8) Bring thermal distortion calculation into the design review.

Checklist

References

GB/T 1800.3-2020 Limits and Fits — Fundamental Deviations

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL