Interference Lost When Cold and Loose When Hot

E43-048 · Uncompensated Thermal Distortion · Chiller Hub · ★★

Problem Symptom

At -30℃ the interference disappeared and the hub came loose

Root Cause

[Cold Contraction] With hub steel α=11e-6, a 60℃ drop produced contraction Δ=11e-6×50×60=0.033mm, cancelling the original 0.03 interference.
[Loosening] The interference turned into clearance, so the hub crept slightly on the shaft and slipped.
[Design Omission] For low-temperature duty the interference should be increased or a key added, and no temperature compensation was designed into the fit.

Correct Solution

1) Increase the low-temperature interference to 0.05~0.06 to offset the contraction;
2) Add a parallel key as an anti-rotation backstop against cold contraction;
3) Carry out a cold contraction calculation to prevent loosening;
4) Match material coefficients of thermal expansion to minimise the difference;
5) Trial-fit cold on the first piece to verify the fit;
6) Verify with a torque test that there is no slipping and torque is transmitted;
7) Monitor during operation to detect failure;
8) Bring temperature compensation into the design review.