E43-094 · Uncompensated Thermal Distortion · Steam Pipeline · ★★★
A 30m pipe with a 180℃ temperature rise elongated ΔL=αLΔT=12e-6×30000×180=64.8mm uncompensated, cracking the flange and causing leakage
[Thermal Elongation] A temperature rise ΔT=180℃ produced elongation ΔL=αLΔT≈65mm.
[Cracking] With no compensation the fixed end carried the force F=EAΔL/L, which exceeded the limit and snapped the flange bolts.
[Design Omission] A bellows expansion joint should have been provided to absorb the elongation, but no thermal elongation calculation was made.
1) Fit a bellows expansion joint;
2) Verify from ΔL=αLΔT;
3) Reinforce the fixed support;
4) Fit a sliding support;
5) Upgrade the flange bolts to high strength;
6) Select the expansion joint with capacity for 65mm;
7) Perform a first-piece pressure test;
8) Modify the supports when out of specification.
GB/T 12777-2008 Metal Bellows Expansion Joints