Temperature Difference Across a Hydraulic Cylinder Causes Sticking

E43-095 · Uncompensated Thermal Distortion · Injection Moulding Machine Clamping Cylinder · ★★

Problem Symptom

A 15℃ temperature difference between the cylinder ends caused 0.04 of distortion, making the piston stick and crawl

Root Cause

[Temperature Difference] A 15℃ difference between the two ends gave an elongation difference ΔL=αLΔT that bent the cylinder.
[Crawling] The distortion caused uneven piston wear and uneven resistance, so the cylinder crawled.
[Design Omission] The oil passages should have been laid out symmetrically to equalise the temperature, but no temperature difference calculation was made.

Correct Solution

1) Lay out the oil passages symmetrically;
2) Apply a temperature equalisation design;
3) Verify from ΔL=αLΔT;
4) Keep the barrel wall thickness even;
5) Cool uniformly;
6) Measure the temperature difference on the first piece;
7) Run a low-speed test;
8) Modify the oil passages when out of specification.

Checklist

References

GB/T 15622-2005 Hydraulic Cylinder Tests