Knowledge Base › Tolerance and Fit Error Case › Industrial Robot Arm Thermal Deformation - Position Drift

Industrial Robot Arm Thermal Deformation - Position Drift

E43-319 · Thermal Deformation Uncompensated · A six-axis robot arm 1200mm long in aluminum alloy, designed thermal compensation, measured 10℃ rise with no compensation · ★★

Problem Description

Arm temperature rise of 10℃ elongated 0.28mm, making repeatability go 0.2mm out of tolerance and welding off.

Root Cause

[Mechanism] The aluminum arm axially expands when heated and drifts the end pose; without compensation, repeatability drops.
[Calculation] Aluminum α=23e-6, Δl=23e-6×1200×10=0.276mm≈0.28mm, exceeding the 0.05mm repeatability tolerance.
[Design Omission] No arm-temperature compensation model — a design defect leading to position drift.

Corrective Solution

1) Build an arm-temperature-to-elongation compensation model to correct the 0.28mm;
2) Embed temperature sensors in the arm for real-time compensation;
3) Use a thermostatic room to hold temperature rise ≤3℃;
4) Select low-expansion arm material or a steel-aluminum composite to cut α;
5) Warm up before machining and re-calibrate;
6) Monitor arm temperature in real time;
7) Periodically re-check repeatability;
8) On first articles, measure positioning and verify error ≤0.05mm.