MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Knowledge Base › Tolerance and Fit Error Case › Centrifugal Fan Impeller Thermal Imbalance - Vibration

Centrifugal Fan Impeller Thermal Imbalance - Vibration

E43-325 · Thermal Deformation Uncompensated · A centrifugal fan impeller ∅1200mm, designed dynamic balance, measured 40℃ rise deformation · ★★

Problem Description

Impeller temperature rise of 40℃ expanded the diameter 0.55mm, making unbalance vibration exceed limits.

Root Cause

[Mechanism] Uneven radial impeller expansion when heated destroys dynamic balance; centrifugal force excites vibration over the limit.
[Calculation] α=11.5e-6, Δd=11.5e-6×1200×40=0.552mm; added eccentricity drives vibration over 4.5mm/s.
[Design Omission] No even temperature rise or re-balancing — a design defect leading to vibration over limit.

Corrective Solution

1) Add an even-temperature structure to the impeller, holding rise ≤15℃;
2) Re-balance hot to G2.5;
3) Add balance weights for hot diameter growth;
4) Monitor vibration in real time with an alarm;
5) Select low-expansion impeller material to cut Δd;
6) Heat the impeller symmetrically to prevent deformation;
7) Re-check dynamic balance periodically;
8) Measure first-article vibration to verify ≤2.8mm/s.

Checklist

Reference

GB/T 3235-2008 Ventilators — Accuracy

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL