E43-326 · Thermal Deformation Uncompensated · A centrifugal pump body 400mm long, designed expansion joint, measured 30℃ rise hard connection · ★★
Pump-body temperature rise of 30℃ elongated 0.14mm, making the mechanical seal leak and the shaft seal weep.
[Mechanism] The pump body axially expands when heated and pulls the seal face off-line; with insufficient mechanical-seal compensation it leaks.
[Calculation] α=11.5e-6, Δl=11.5e-6×400×30=0.138mm≈0.14mm, exceeding the 0.1mm seal compensation and leaking.
[Design Omission] No expansion joint or seal compensation — a design defect leading to leak.
1) Add a pump-body expansion joint to absorb the 0.14mm elongation;
2) Leave mechanical-seal compensation ≥0.2mm;
3) Add flexible connections at inlet/outlet to prevent pulling off-line;
4) Monitor seal temperature in real time;
5) Select low-expansion pump-body material to cut Δl;
6) Add cooling to the seal face;
7) Periodically check leakage;
8) Pressure-test the first article to verify no leakage.
GB/T 5656-2008 Centrifugal pumps — Technical specifications