E43-328 · Thermal Deformation Uncompensated · An open-front press slide 2000mm wide, designed temperature equalization, measured 12℃ one-sided rise · ★★
Slide temperature rise of 12℃ tilted it, making perpendicularity go 0.1mm out of tolerance and causing uneven die wear.
[Mechanism] One-sided slide heating tilts it and the slide is no longer perpendicular to the table; off-center die loading causes uneven wear.
[Calculation] α=11.5e-6, Δl=11.5e-6×2000×12=0.276mm≈0.28mm; the tilt drives perpendicularity error to 0.1mm.
[Design Omission] No temperature equalization or perpendicularity compensation — a design defect leading to perpendicularity out of tolerance.
1) Add slide temperature equalization, holding rise ≤6℃;
2) Add perpendicularity compensation and true it to ≤0.03mm;
3) Symmetrically place ribs to reduce tilt;
4) Monitor slide temperature in real time;
5) Use low-expansion material to reduce Δl;
6) Add die guidance to remove uneven wear;
7) Periodically re-measure perpendicularity;
8) On first articles, measure perpendicularity and verify ≤0.03mm.
GB/T 10923-2005 Forging and stamping machinery — Accuracy