Knowledge Base › Tolerance and Fit Error Case › Welding-Positioner Turn-Table Thermal Warpage - Flatness

Welding-Positioner Turn-Table Thermal Warpage - Flatness

E43-330 · Thermal Deformation Uncompensated · A welding positioner turn-table ∅2000mm in cast iron, designed temperature equalization, measured 15℃ one-sided rise · ★★

Problem Description

Table temperature rise of 15℃ warped it 0.3mm, making flatness go 0.15mm out of tolerance and shifting the workpiece.

Root Cause

[Mechanism] One-sided table heating warps it and the workpiece locating face tilts; the welding position shifts.
[Calculation] α=10e-6, Δl=10e-6×2000×15=0.3mm; the warpage drives flatness error to 0.15mm.
[Design Omission] No temperature equalization or compensation — a design defect leading to flatness out of tolerance.

Corrective Solution

1) Add turn-table temperature equalization, holding rise ≤8℃;
2) Add thermal compensation to correct the 0.15mm flatness;
3) Symmetrically place ribs to reduce warpage;
4) Monitor table temperature in real time;
5) Select low-expansion cast iron to cut Δl;
6) Add workpiece locating pins to prevent shift;
7) Re-check flatness periodically;
8) On first articles, measure flatness and verify ≤0.05mm.

Checklist

Reference

GB/T 1184-1996 Shape and position tolerances - Undefined tolerances