E43-336 · Thermal Deformation Uncompensated · A reducer train with 2000mm shaft center distance, designed cold alignment, measured 30℃ rise shift · ★★

Problem Description

A 30℃ temperature rise made the two shafts elongate unequally, shifting alignment 0.1mm and causing vibration and noise.

Root Cause

[Mechanism] Different materials or temperatures make the two shafts elongate unequally, breaking coupling alignment; added bending moment causes vibration.
[Calculation] Elongation difference Δl=(α1−α2)·l·ΔT; steel vs. cast difference 1.5e-6×2000×30=0.09mm≈0.1mm.
[Design Omission] No hot-state alignment check — a design defect leading to alignment shift.

Corrective Solution

1) Pre-offset train alignment by 0.1mm for the hot elongation difference;
2) Choose the same or near-CTE material for both shafts to remove the difference;
3) Monitor shaft temperature in real time;
4) Add an intermediate spacer to the coupling for compensation;
5) Leave expansion gaps at anchor bolts;
6) Periodically re-check hot-state alignment;
7) Monitor vibration and alarm;
8) On first articles, hot-run and verify vibration ≤2.8mm/s.