E43-340 · Thermal Deformation Not Compensated · An axle-box body 200mm long, designed clearance, measured rise 50℃ with no compensation · ★★
A 50℃ axle-box temperature rise expands it by 0.115mm, causing bearing seizure and axle lock.
[Mechanism] The axle box expands under heat, shrinking the bearing bore; the fit clearance disappears and the axle seizes.
[Calculation] α=11.5e-6, Δl=11.5e-6×200×50=0.115mm; the 0.08mm clearance is fully consumed and the joint seizes.
[Design Omission] No hot-state clearance was provided — a design defect leading to seizure.
1) Size the bearing-bore clearance for hot-state growth, ≥0.15mm;
2) Add cooling to the axle box to hold the rise ≤30℃;
3) Select a larger-clearance bearing class to accommodate heat;
4) Monitor axle temperature in real time with an alarm;
5) Use low-expansion box material to reduce Δl;
6) Re-check clearance periodically;
7) Run the first article to verify no seizure;
8) Monitor axle temperature in service.
GB/T 12814-2002 Rolling bearings for railway locomotives and rolling stock