E43-346 · Thermal Deformation Not Compensated · A tank 2000mm long, designed breather, measured rise 20℃ with none applied · ★★

Problem Description

A 20℃ tank temperature rise elongates it by 0.46mm, stressing the welds until they crack and seep oil.

Root Cause

[Mechanism] The tank expands under heat but is constrained; internal stress concentrates at the welds, which crack and leak.
[Calculation] α=11.5e-6, Δl=11.5e-6×2000×20=0.46mm; the constraint stress exceeds the weld strength and it cracks.
[Design Omission] No breather was provided to relieve expansion — a design defect leading to weld cracking.

Corrective Solution

1) Fit a breather to the tank to relieve the 0.46mm expansion;
2) Add an expansion joint or flexible connection at the welds;
3) Monitor tank temperature in real time;
4) Use low-expansion tank material to reduce Δl;
5) Stress-relieve the welds after welding;
6) Inspect for leakage periodically;
7) Add stiffeners to the tank to spread the stress;
8) Pressure-test the first article to verify no leakage.

Checklist

Reference

GB/T 3766-2015 Hydraulic systems — General technical requirements