E43-347 · Thermal Deformation Not Compensated · An aluminum guard 3000mm long, designed expansion joint, measured rise 15℃ with none applied · ★★
A 15℃ guard temperature rise elongates it by 1.03mm, making the guard interfere with the bed and seize.
[Mechanism] The aluminum guard expands under heat with no expansion joint and rigidly interferes with the bed, seizing as it slides.
[Calculation] Aluminum α=23e-6, Δl=23e-6×3000×15=1.035mm≈1.03mm, exceeding the available clearance and causing interference.
[Design Omission] No expansion joint was provided — a design defect leading to interference and seizure.
1) Provide an expansion joint in the guard to absorb the 1.03mm elongation;
2) Add cooling to the guard to hold the rise ≤8℃;
3) Leave sliding clearance against the bed;
4) Monitor guard temperature in real time;
5) Use low-expansion aluminum to reduce Δl;
6) Lubricate the guides to prevent binding;
7) Check for interference periodically;
8) Cycle the first article to verify no seizure.
GB/T 17421.1-1998 Test code for machine tools — Part 1