E43-357 · Welded/Cast Forming Dimensional Error · A reducer casing with 3mm mold shift at the parting line, designed two-bore coaxiality φ0.05, measured eccentricity 3 · ★★★
Casting mold shift offsets the upper and lower bearing bores by 3mm, pushing coaxiality out of tolerance and scoring the shaft.
[Mechanism] Misalignment of the cope and drag at the parting line offsets the upper and lower bore centerlines; after boring the two bores are not coaxial.
[Calculation] Coaxiality deviation≈mold-shift e/2=3/2=1.5 (measured eccentricity 3 due to one-sided shift), hundreds of times the φ0.05 limit.
[Design Omission] No match-plate dowels or mold-shift control — a design defect leading to coaxiality error.
1) Provide match-plate dowels to control mold shift ≤0.5mm;
2) Before boring, scribe a full circle to align the centerline;
3) Machine cope and drag in the same setup order to keep coaxiality;
4) Improve mold precision to reduce shift;
5) Rough and finish-bore in one setup;
6) Check coaxiality with a mandrel;
7) Provide a register lip to prevent misalignment;
8) Measure first-article coaxiality ≤0.05mm.
GB/T 11336-2004 Straightness tolerances