E43-369 · Welded/Cast Forming Dimensional Error · An equipment frame 2000×1500mm, designed diagonal mismatch ≤2, measured post-weld 7 · ★★
Uneven weld shrinkage of the frame gives a 7mm diagonal mismatch and shifts the assembly holes.
[Mechanism] Asymmetrically distributed weld shrinkage makes the two diagonals unequal, skewing the frame.
[Calculation] Diagonal mismatch Δ≈√(a²+b²+2ab·cosγ)-√(a²+b²)≈7mm (angular distortion γ≈0.3°), 3.5× the tolerance of 2.
[Design Omission] No symmetric welding or fixture location — a design defect leading to diagonal mismatch error.
1) Use a welding fixture to control the outline;
2) Weld symmetrically in skip passes to reduce shrinkage bias;
3) Pre-set anti-distortion before welding;
4) Add temporary diagonal bracing;
5) Control heat input;
6) Correct after welding;
7) Measure diagonals with a steel tape;
8) Measure first-article diagonal mismatch ≤2mm.
GB/T 50205-2020 Standard for acceptance of construction quality of steel structures