MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Knowledge Base › Tolerance and Fit Error Case › Pressure-Vessel Head Spinning Thinning Error

Pressure-Vessel Head Spinning Thinning Error

E43-379 · Welded/Cast Forming Dimensional Error · A head 1200mm diameter, 10mm plate, designed thinning ≤1, measured 2.8 · ★★

Problem Description

Spinning/stretching the head thins the crown by 2.8mm, leaving insufficient strength.

Root Cause

[Mechanism] During head spinning the plate is stretched and thinned; the crown thins most and exceeds tolerance.
[Calculation] Thinning rate≈(10-7.2)/10=28%; the 2.8mm thinning is 2.8× the tolerance of 1.
[Design Omission] No control of the spinning process or thickened blank — a design defect leading to wall-thickness error.

Corrective Solution

1) Oversize the head blank by 2.8mm to compensate;
2) Optimize the spinning stretch ratio;
3) Control even blank-holder force;
4) Form in multiple passes to reduce thinning;
5) 100% inspect with a thickness gauge;
6) Improve die surface finish;
7) Design a thickened crown zone;
8) Measure first-article wall thickness to spec.

Checklist

Reference

GB/T 25198-2010 Pressure vessel heads

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL